We understand how difficult it is to be without power. We have rested crews when possible, staged equipment and stocked trucks. We are also proactively opening local storm bases and our Emergency Coordination Center and are bringing in crews from outside the area. Crews will remain in the field to assess damage and restore power as long as it is safe. If your power goes out, we’ll work around the clock to restore it as quickly and safely as possible.

Visit PSE’s Alerts and Advisories page for information on our response efforts: pse.com/alerts.


alert 

Safety first. Never touch or go within 35 feet of downed power lines because they might be energized. Call PSE at 1-888-225-5773 or 911 to report problems.

Report and track power outages online

Commercial Midstream HVAC and Water Heating Program

The Puget Sound Energy (PSE) Midstream HVAC and Water Heating program is designed to promote the benefits of energy-efficient HVAC and water heating systems. Participating distributors can pass through a discount if the unit being purchased meets the criteria below.

Rebates are available for:

 

End-use customers* can expect the equipment rebate from their contractor. Ask your contractor or distributor about receiving a discount on your new high-efficiency electric heat pump or condensing gas storage water heater. Contact your preferred contractor or you can find one here.

Reference Tables, below, for qualifying products. Equipment incentives are passed down to end-use customers* through participating distributors.

*End-use customers are PSE electric or gas customers who purchase qualifying equipment from a participating distributor or contractor.


Heat Pumps

Table 1: SEER2/HSPF2 rated air-cooled heat pumps (<5.4 tons)
EQUIPMENT / PROJECT TYPE TIER SEER2 HSPF2 Rebate ($ PER UNIT)
Air-source heat pumps
Mini-/multi-split, split, or packaged
Retrofit or new construction
3 16 9.5 $600 total rebate
$210 to Distributor/ Contractor
$390 to End-Use Customer
Air-source heat pumps
Mini-/multi-split, split, or packaged
Retrofit or new construction
2 15.2 8.5 $400 total rebate
$130 to Distributor/ Contractor
$270 to End-Use Customer
Air-source heat pumps
Mini-/multi-split, split, or packaged
Retrofit only
1 15.2 8.1 $300 total rebate
$90 to Distributor/ Contractor
$210 to End-Use Customer
ask advisor
Join our Midstream Program

Are you a distributor or contractor? Learn more about PSE’s Midstream program. Contact Us at psemidstreamteam@icf.com

info construction
Need a contractor?

Request a PSE Recommended Energy Professional (REP) to complete your energy efficient improvement upgrade.

Table 2: PSE-approved heat pumps >5.4 tons2
Project
Type
Building Type Equipment Type Min. tons Max. tons Tier Minimum Cooling Efficiency 1 Minimum Cooling Efficiency 2 Minimum Heating Efficiency Total rebate ($/ton) Distr./contr. rebate ($/ton) End user rebate ($/ton)
Retrofit
or new construction
Commercial
/
Multifamily
Air-cooled 5.4 11.3 1 11.3 EER 15.4 IEER 3.5 COP $100 $40 $60
2 11.3 EER 18 IEER 3.5 COP $125 $50

$75

11.3 20 1 11 EER 14.8 IEER 3.3 COP $100 $40 $60
2 11 EER 18.5 IEER 3.3 COP $125 $50 $75
20 63.3 1 10.1 EER 13 IEER 3.2 COP $100 $40 $60
2 10.1 EER 14 IEER 3.2 COP $125 $50 $75
Water-cooled 0 1.4 1 14 EER - 4.6 COP $50 $20 $30
2 15 EER - 4.6 COP $75 $30

$45

3 16 EER - 4.6 COP $125 $50 $75

Water-cooled
(closed-loop geothermal)

0 11.3 1 15 EER - 3.5 COP $125 $50 $75
Water-cooled
(open-loop geothermal)
1 19 EER - 4 COP $125 $50 $75

2 Customers purchasing qualifying heat pump systems must have a valid electric service account with Puget Sound Energy.

Air Conditioners

Table 3: PSE-approved commercial/multifamily air conditioning measures3

Limit 1 unit per commercial retrofit project. Limit 2 per commercial new construction project.

Project
Type
Building Type Equipment Type Min. tons Max. tons Minimum Cooling Efficiency 1 Minimum Cooling Efficiency 2 Tier Total rebate ($/ton) Distr./contr. rebate ($/ton) End user rebate ($/ton)
Retrofit
or new construction
Commercial
/
Multifamily
Water/evaporatively cooled 0 5.4 13.5 EER 14 IEER 1 $50 $20 $30
5.4 11.3 13 EER 15.5 IEER
11.3 20 - -
20 63.3 15 EER 14.5 IEER $40 $16 $24
63.6 - - -
Air-cooledWater-cooled 5.4 11.3 11.5 EER 15.4 IEER 1 $65 $26 $39
- 18 IEER 2 $100 $40 $60
- 21 IEER 3 $125 $50 $75
11.3 20 11.4 EER 14.8 IEER 1 $65 $26 $39
- 16.5 IEER 2 $100 $40

$60

- 18.5 IEER 3 $125 $50 $75
20 63.3 10.1 EER 14 IEER 1 $65 $26 $39
- 15 IEER 2 $100 $40 $60
- 16.5 IEER 3 $125 $50 $75
63.3 - 9.8 EER 13 IEER 1 $40 $16 $24
- 14 IEER 2 $65 $26 $39
- 16 IEER 3 $125 $50 $75

3Customers purchasing qualifying air conditioning systems must have a valid electric service account with Puget Sound Energy.

  • What is SEER(2)? HSPF(2)?

    Seasonal Energy Efficiency Ratio (SEER/SEER2) is most commonly used to measure the efficiency of a central air conditioner. The higher the SEER, the more efficient the system. SEER measures how efficiently a cooling system will operate over an entire season. In technical terms, SEER is a measure of the total cooling of a central air conditioner or heat pump (in Btu) during the normal cooling season as compared to the total electric energy input (in watt-hours) consumed during the same period. This measure of efficiency is specific to the temperate climate in the middle of the U.S. Recently testing procedures have been refined to introduce the SEER2 rating.

    Heat Seasonal Performance Factor (HSPF/HSPF2) is the most commonly used measure of a heat pumps heating efficiency. The higher the HSPF, the more efficient the heat pump. In technical terms, HSPF represents the total heating output of a heat pump (including supplementary electric heat) during the normal heating season (in Btu) as compared to the total electricity consumed (in watt-hours) during the same period. Recently testing procedures have been refined to introduce the HSPF2 rating.

    Source: www.energystar.gov

  • Ductless heat pump facts

    A ductless heat pump is a highly energy-efficient heating and cooling system that runs without the energy losses associated with the ductwork of a central forced-air system. As it doesn't require ducts to carry conditioned air, it is the preferred system for additions to your home, newer homes that only require a small space conditioning system or areas of your home that you wish to condition in zones.

    Other benefits include:

    • Ductless heat pumps use between 25 and 50 percent less energy to heat your home
    • An ultra-quiet fan evenly circulates air, eliminating hot and cold spots
    • Installation in your home is inexpensive, simple and quick, which makes for little or no disruption
    • Ductless systems come standard with air conditioning, so you can get rid of window units
  • Air-source heat pump facts

    airsourceheatpump

    An air-source heat pump is a high-efficiency heating and cooling system that can deliver between one-and-a-half and three times more heat energy to a home than the electrical energy it uses.

    A less efficient panel of electric coils kicks in to provide additional indoor heating when outdoor temperatures fall below 40 degrees Fahrenheit, so it's generally not a preferred system for regions with sub-freezing winter temperatures.

Water heaters

Commercial/Multifamily Water Heaters

Table 4: PSE-approved commercial/multifamily water heating measures
Project
Type
Building Type Water heater
type
Input
rating
Minimum
Efficiency
Average
input
MBtuh
rating
Total
rebate
($/MBtuh)
Distributor/
contractor
rebate
($/MBtuh)
End user
rebate
($/MBtuh)
Retrofit
or new
construction
Commercial/
multifamily
Condensing
gas storage
tank water
heaters
≥ 75
MBtuh
TE ≥ 90% or
UEF ≥ 0.90
212 $5 $2 $3
Condensing
gas tankless
water heaters
< 300
MBtuh
TE ≥ 95% or
UEF ≥ 0.95
198 $3 $1.20 $1.80
Condensing
gas domestic
hot water
boilers
≥ 300
MBtuh
TE ≥ 90% 749 $5 $2 $3

Customers purchasing qualifying gas water heater systems must have a valid natural gas service account with Puget Sound Energy.

alert

TIP: The installation of a heat pump or air conditioner can sometimes cause a fluctuation in the power supply when your equipment starts. This may result in a visible flicker of the lighting in your home or your neighbors' homes.

To ensure that your heat pump installation does not have a negative effect on power quality, it's important to discuss this issue with your contractor. For additional assistance, call a PSE Customer Construction Services specialist at 1-888-321-7779.